Stranded Aluminum Wire Sizes
Aluminum wires come in different types.
Stranded aluminum wire sizes. Wire gauge refers the physical size of the wire rated with a numerical designation that runs opposite to the diameter of the conductors in other words the smaller the wire gauge number the larger the wire diameter. Covered aerial mv. Wire gauge calculations wire diameter calculations. Types thwn and rhw are the most commonly used ones.
For a 50 amp aluminum wire use no 4 awg. American wire gauge size calculator and chart. 4 is bigger in size than no. The n gauge wire diameter d n in millimeters mm is equal to 0 127mm times 92 raised to the power of 36 minus gauge.
Helps determine the proper wire size for an electrical circuit based on the voltage drop and current carrying capacity of an electrical circuit. 60 c 140 f 75 c 167 f awg mm copper. Of wires mm in mm in mm in mm in 20 1020 0 517 00080 7 0 31 0121 91 036. Aluminum 600 volt secondary distribution.
Bare aluminum overhead transmission distribution. Stranded bare copper and aluminum conductors dimensions nominal conductor conductor diameter size area wire diameter class b standard compressed round compact round awg cir mils mm 2 sq in no. The wire size chart below shows allowable ampacities of insulated conductors rated up to and including 2000 volts 60 c through 90 c 140 f through 194 f not more than three current carrying conductors in raceway cable or earth directly buried based on ambient air temperature of 30 c 86 f. The n gauge wire diameter d n in inches in is equal to 0 005in times 92 raised to the power of 36 minus gauge number n divided by 39.
Nominal size of conductor number of wires diameter of individual wires inches overall conductor diameter inches lbs. Wire is sized by the american wire gauge awg system. 1 the load current rating and the overcurrent protection for conductor types shall not exceed 15 amperes for 14 awg 20 amperes for 12 awg and 30 amperes for 10 awg aluminum and copper clad aluminum after any correction factors for ambient temperature and number of conductors have been applied. Common sizes include 14 12 10 8 6 and 2 gauge wire.
Break strength lbs kg maximum dc resistance ohms 1 000 ohms km circular area 56 1 s solid 0 00049 0 0124 0 24 0 00012 0 00070 0 001 0 0066 0 00. 6 is only good up to 40 amp. The tables below are intended to be a general guide for wire size and amp ratings. Wire stranding charts solid and stranded conductor awg chart awg size total strands strand size type construction nominal diameter inches mm mils mm2 approimate weight lbs 1000 kg km nom.